Sensors (Dec 2023)

Vibration and Slope Conditions during Harvesting Affect Radish Mass Measurements for Yield Monitoring: An Experimental Study Using a Laboratory Test Bench

  • Shafik Kiraga,
  • Md Nasim Reza,
  • Milon Chowdhury,
  • Md Ashraffuzzaman Gulandaz,
  • Mohammod Ali,
  • Md Sazzadul Kabir,
  • Eliezel Habineza,
  • Md Shaha Nur Kabir,
  • Sun-Ok Chung

DOI
https://doi.org/10.3390/s23249744
Journal volume & issue
Vol. 23, no. 24
p. 9744

Abstract

Read online

Site-specific measurements of the crop yield during harvesting are essential for successfully implementing precision management techniques. This study aimed to estimate the mass of radish tubers using the impact principle under simulated vibration and sloped-field harvesting conditions with a laboratory test bench. These conditions included the conveyor speed (CS), impact plate layout (IP), falling height onto the impact plate (FH), the plate angle relative to the horizontal (PH), the field slope, and the vibration of the harvesting machine. Two layouts of impact-type sensors were fabricated and tested, one with a single load cell (SL) and the other with two load cells (DL). An adjustable slope platform and a vibration table equipped with vibration blades were utilized to simulate the slope and vibration effects, respectively. Calibrations were conducted to verify the accuracy of the sensor outputs, processed with the finite impulse response and moving average filters. Radish mass was estimated using an asymmetrically trimmed mean method. The relative percentage error (RE), standard error (SE), coefficient of determination (R²), and analysis of variance (ANOVA) were used to assess the impact plate performance. The results indicated that the SE for both impact plates was less than 4 g in the absence of vibration and slope conditions. The R2 for the single and double impact plates ranged from 0.58 to 0.89 and 0.69 to 0.81, respectively. The FH had no significant impact, while the PH significantly affected the mass measurements for both impact plates. On the other hand, the CS significantly affected the plate performance, except for the double-load-cell impact plate. Both vibration and slope affected the mass measurements, with RE values of 9.89% and 13.92%, respectively. The RE for filtered radish signals was reduced from 9.13% to 5.42%. The tests demonstrated the feasibility of utilizing the impact principle to assess the mass of radishes, opening up possibilities for the development of yield-monitoring systems for crops harvested in a similar manner.

Keywords