Entropy (Jun 2004)

Effect of Magnetic Field on Entropy Generation Due to Laminar Forced Convection Past a Horizontal Flat Plate

  • Moh'd A. Al-Nimr,
  • Renhe A. Damseh,
  • Mohammed Q. Al-Odat

DOI
https://doi.org/10.3390/e6030293
Journal volume & issue
Vol. 6, no. 3
pp. 293 – 303

Abstract

Read online

Magnetic field effect on local entropy generation due to steady two-dimensional laminar forced convection flow past a horizontal plate was numerically investigated. This study was focused on the entropy generation characteristics and its dependency on various dimensionless parameters. The effect of various dimensionless parameters, such as Hartmann number (Ha), Eckert number (Ec), Prandtl number (Pr), Joule heating parameter (R) and the free stream temperature parameter (θ∞) on the entropy generation characteristics is analyzed. The dimensionless governing equations in Cartesian coordinate were solved by an implicit finite difference technique. The solutions were carried out for Ha2=0.5-3, Ec=0.01-0.05, Pr=1-5 and θ∞=1.1-2.5. It was found that, the entropy generation increased with increasing Ha, Ec and R. While, increasing the free stream temperature parameter, and Prandtl number tend to decrease the local entropy generation.

Keywords