Nuclear Engineering and Technology (Jan 2023)

Validation of electromagnetic physics models and electron range in Geant4 Brachytherapy application

  • A. Albqoor,
  • E. Ababneh,
  • S. Okoor,
  • I. Zahran

Journal volume & issue
Vol. 55, no. 1
pp. 229 – 237

Abstract

Read online

The mechanics underlying photon and electron interactions was validated using our developed Brachytherapy computer code for high Dose Rate (HDR). By comparing the photon cross-section utilizing multiple physics libraries in the developed code, the results were benchmarked against experimental and theoretical findings. Klein-Nishina and experimental cross-section results were in good agreement with the Livermore library results. For two therapeutically relevant materials, the first scattered electron range was measured within 1 mm and 2 mm, which has significant implications for the interpretation of the kernel dose spikes observed in previous research.