Modeling, Identification and Control (Jan 1994)

A new recontruction algorithm for use with capacitance-based tomography

  • Ø. Isaksen,
  • J.E. Nordtvedt

DOI
https://doi.org/10.4173/mic.1994.1.2
Journal volume & issue
Vol. 15, no. 1
pp. 9 – 21

Abstract

Read online

A new reconstruction algorithm for use with capacitance-based process tomography is proposed. A numerical simulator, capable of calculating the capacitances for a particular sensor configuration and flow regime is used together with a parameter representation of the dielectric distribution and an optimization algorithm. The algorithm calculates these parameters and hence the dielectric distribution, by minimizing a function defined as a weighted sum of square differences between the measured and estimated capacitances. The method is tested by using both synthetic and experimental data, and the results are compared with results from the commonly used Linear Back Projection (LBP) algorithm. The method is capable of obtaining the correct parameter values for all the flow regimes tested, and does provide a better estimate than the LBP method. The method proves to be very promising, and is a step towards quantitative capacitance tomography.

Keywords