Development of a UHPLC-MS/MS Method for the Determination of Moxidectin in Rat Plasma and Its Application in Pharmacokinetics
Hongjuan Zhang,
Zhen Yang,
Baocheng Hao,
Di Wu,
Dan Shao,
Yu Liu,
Wanxia Pu,
Shouli Yi,
Ruofeng Shang,
Shengyi Wang
Affiliations
Hongjuan Zhang
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Zhen Yang
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Baocheng Hao
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Di Wu
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Dan Shao
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Yu Liu
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Wanxia Pu
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Shouli Yi
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Ruofeng Shang
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
Shengyi Wang
Key Laboratory of New Animal Drug Project, Gansu Province/Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs/Lanzhou Institute of Husbandry and Pharmaceutical Sciences of CAAS, Lanzhou 730050, China
The aim of the present study was to establish a simple and reliable ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method and apply it for the determination of pharmacokinetics of moxidectin-loaded microspheres (MOX-MS) in rats. Plasma samples were processed using a simplified liquid–liquid extraction method and were separated using an Agilent Zorbax Eclipse Plus C18 column (50 mm × 2.1 mm, 1.8 μm) with a mobile phase consisting of a 10 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) at a flow rate of 0.4 mL/min for 5 min. Avermectin B1a was used as an internal standard (IS). The sample was injected at a volume of 10 μL with a column temperature of 35 °C and detected in a positive ion mode. A good linear response across the concentration range of 1.00–200 ng/mL (r2 > 0.99) and a lower limit of quantification (LLOQ) of 1.00 ng/mL were achieved. The extraction recovery of moxidectin exceeded 94.1%, the matrix effect was between 91.2% and 96.2%, the accuracy ranged from 100.1 to 103.6%, and the relative standard deviation (RSD) did not exceed 15% for the intra- and inter-day accuracy and precision. The pharmacokinetic results showed that MOX-MS significantly decreased Cmax, prolonged T1/2, and improved bioavailability. The developed method significantly reduced the assay volume, shortened detection time, simplified sample processing methods and saved assay costs, which may contribute to the development of the new antiparasitic drug.