Experimental investigation of thermal conductivity coefficient and heat exchange between fluidized bed and inclined exchange surface

Brazilian Journal of Chemical Engineering. 2009;26(2):343-352 DOI 10.1590/S0104-66322009000200011

 

Journal Homepage

Journal Title: Brazilian Journal of Chemical Engineering

ISSN: 0104-6632 (Print); 1678-4383 (Online)

Publisher: Brazilian Society of Chemical Engineering

LCC Subject Category: Technology: Chemical technology: Chemical engineering

Country of publisher: Brazil

Language of fulltext: English

Full-text formats available: PDF, HTML, XML

 

AUTHORS

B. Stojanovic
J. Janevski
M. Stojiljkovic

EDITORIAL INFORMATION

Peer review

Editorial Board

Instructions for authors

Time From Submission to Publication: 12 weeks

 

Abstract | Full Text

The paper presents experimental research of thermal conductivity coefficients of the siliceous sand bed fluidized by air and an experimental investigation of the particle size influence on the heat transfer coefficient between fluidized bed and inclined exchange surfaces. The measurements were performed for the specific fluidization velocity and sand particle diameters d p=0.3, 0.5, 0.9 mm. The industrial use of fluidized beds has been increasing rapidly in the past 20 years owing to their useful characteristics. One of the outstanding characteristics of a fluidized bed is that it tends to maintain a uniform temperature even with nonuniform heat release. On the basis of experimental research, the influence of the process's operational parameters on the obtained values of the bed's thermal conductivity has been analyzed. The results show direct dependence of thermal conductivity on the intensity of mixing, the degree of fluidization, and the size of particles. In the axial direction, the coefficients that have been treated have values a whole order higher than in the radial direction. Comparison of experimental research results with experimental results of other authors shows good agreement and the same tendency of thermal conductivity change. It is well known in the literature that the value of the heat transfer coefficient is the highest in the horizontal and the smallest in the vertical position of the heat exchange surface. Variation of heat transfer, depending on inclination angle is not examined in detail. The difference between the values of the relative heat transfer coefficient between vertical and horizontal heater position for all particle sizes reduces by approximately 15% with the increase of fluidization rate.