Rapid Separation of Enantiomeric Impurities in Chiral Molecules by a Self-Referential Weak Measurement System
Yang Xu,
Lixuan Shi,
Tian Guan,
Suyi Zhong,
Xuesi Zhou,
Dongmei Li,
Cuixia Guo,
Yuxuan Yang,
Xiangnan Wang,
Zhangyan Li,
Yonghong He,
Luyuan Xie,
Zonghan Gan
Affiliations
Yang Xu
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Lixuan Shi
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Tian Guan
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Suyi Zhong
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Xuesi Zhou
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Dongmei Li
Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
Cuixia Guo
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Yuxuan Yang
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Xiangnan Wang
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Zhangyan Li
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Yonghong He
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Luyuan Xie
Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
Zonghan Gan
Division of biomedical engineering, University of Glasgow, 89 Dumbarton Rd, Glasgow G12 8QQ, UK
We propose a self-referential fast detection scheme for a frequency domain weak measurement system for the detection of enantiomeric impurities in chiral molecules. In a transmissive weak measurement system, the optical rotation (OR) is used to modify the pre-selected polarization state and the post-selection polarization state. We obtained the sum and difference of the optical rotations produced by the sample and the standard by rotating the quarter wave plate in the system. Then, we estimate the ratio of chiral molecules to enantiomeric impurities using the ratio of the central wavelength shifts caused by the addition and subtraction states described above. In this paper, our system has an optical resolution of 1.88 × 10−5°. At the same time, we completed the detection of the ratio of the two substances in the mixture of L-proline and D-proline in different proportions, which proved that our system can quickly detect the content of enantiomeric impurities in chiral molecules.