Tomography (Jul 2021)

High Rate of False Negative Diagnosis of Silent Patent Ductus Arteriosus on the Chest CT with 3 mm Slice-Thickness, Suggesting the Need for Analysis with Thinner Slice Thickness

  • Dongjun Lee,
  • Minji Son,
  • Seungmin Yoo,
  • Sanghoon Jung,
  • Eunju Chun,
  • Charles S. White

DOI
https://doi.org/10.3390/tomography7030025
Journal volume & issue
Vol. 7, no. 3
pp. 278 – 285

Abstract

Read online

The purpose of this study was to evaluate the diagnostic accuracy of patent with ductus arteriosus (PDA) based on the availability of pretest information on routine chest CT with 3 mm slice-thickness. We retrospectively evaluated CT of 64 patients with PDA. The enrolled patients were categorized as group 1 (presence of pretest information) and 2 (absence of pretest information, silent PDA). CTs were read by eleven board-certified radiologists, and subsequently by two blind readers. We investigated whether a PDA was mentioned on the initial CT reading. Correct diagnosis of PDA was made in all patients with group 1 (n = 42). In contrast, only 13.7% were correctly diagnosed in group 2. All cases of missed PDA in group 2 were also missed by two blind readers. It is important to realize that the diagnostic accuracy of silent PDA is poor on the chest CT with 3 mm slice-thickness. Thus, use of axial CT images with the thinnest slice-thickness and multi-planar reformatted images (i.e., sagittal and coronal images) may be one way to reduce the number of missed PDA.