MATEC Web of Conferences (Jan 2016)
Means of regulating combustible materials and products in external walls
Abstract
This report presents proposals for defining means of regulating the use of combustible materials and products in external walls. Required protections are based on the quantities of fire loads and their contribution to fire development. The study is based on life safety and protection of property priorities taking into account reaction to fire classes related to different types of fire loads and fire compartmentation requirements of the adjacent spaces of concern. The proposals include the following main principles in relation to fire-separation requirements: In case of internal fire exposure the protective structure for combustible building parts needs to meet at least half of the fire-separating requirement for the compartment of concern. In case of external fire exposure the protection time requirement can be 15 minutes less than for the internal protection. The proposals are applicable for residential buildings and offices. In case of buildings with longer evacuation times more stringent requirement levels may be considered. For verification of protection performance of fire loads it is proposed to use existing standardized test methods (fire protection ability (K classes) and fire-separating function (EI classes) validated methods of calculation and/or large scale fire testing.