Cardiovascular Ultrasound (Apr 2022)
Cardiac microstructural alterations in immune-inflammatory myocardial disease: a retrospective case-control study
Abstract
Abstract Background Immune-inflammatory myocardial disease contributes to multiple chronic cardiac processes, but access to non-invasive screening is limited. We have previously developed a method of echocardiographic texture analysis, called the high-spectrum signal intensity coefficient (HS-SIC) which assesses myocardial microstructure and previously associated with myocardial fibrosis. We aimed to determine whether this echocardiographic texture analysis of cardiac microstructure can identify inflammatory cardiac disease in the clinical setting. Methods We conducted a retrospective case-control study of 318 patients with distinct clinical myocardial pathologies and 20 healthy controls. Populations included myocarditis, atypical chest pain/palpitations, STEMI, severe aortic stenosis, acute COVID infection, amyloidosis, and cardiac transplantation with acute rejection, without current rejection but with prior rejection, and with no history of rejection. We assessed the HS-SIC’s ability to differentiate between a broader diversity of clinical groups and healthy controls. We used Kruskal-Wallis tests to compare HS-SIC values measured in each of the clinical populations with those in the healthy control group and compared HS-SIC values between the subgroups of cardiac transplantation rejection status. Results For the total sample of N = 338, the mean age was 49.6 ± 20.9 years and 50% were women. The mean ± standard error of the mean of HS-SIC were: 0.668 ± 0.074 for controls, 0.552 ± 0.049 for atypical chest pain/palpitations, 0.425 ± 0.058 for myocarditis, 0.881 ± 0.129 for STEMI, 1.116 ± 0.196 for severe aortic stenosis, 0.904 ± 0.116 for acute COVID, and 0.698 ± 0.103 for amyloidosis. Among cardiac transplant recipients, HS-SIC values were 0.478 ± 0.999 for active rejection, 0.594 ± 0.091 for prior rejection, and 1.191 ± 0.442 for never rejection. We observed significant differences in HS-SIC between controls and myocarditis (P = 0.0014), active rejection (P = 0.0076), and atypical chest pain or palpitations (P = 0.0014); as well as between transplant patients with active rejection and those without current or prior rejection (P = 0.031). Conclusions An echocardiographic method can be used to characterize tissue signatures of microstructural changes across a spectrum of cardiac disease including immune-inflammatory conditions.
Keywords