Condition Assessment of HV Bushings with Solid Insulation based on the SVM and the FDS Methods
Jan Subocz,
Andrzej Mrozik,
Patryk Bohatyrewicz,
Marek Zenker
Affiliations
Jan Subocz
Faculty of Electrical Engineering, Department of Electrotechnology and Diagnostics, West Pomeranian University of Technology, Sikorskiego 37, 70–313 Szczecin, Poland
Andrzej Mrozik
Faculty of Electrical Engineering, Department of Electrotechnology and Diagnostics, West Pomeranian University of Technology, Sikorskiego 37, 70–313 Szczecin, Poland
Patryk Bohatyrewicz
Faculty of Electrical Engineering, Department of Electrotechnology and Diagnostics, West Pomeranian University of Technology, Sikorskiego 37, 70–313 Szczecin, Poland
Marek Zenker
Faculty of Electrical Engineering, Department of Electrotechnology and Diagnostics, West Pomeranian University of Technology, Sikorskiego 37, 70–313 Szczecin, Poland
This paper presents the dielectric response of the insulation of bushings as an effect of the simulated long-term aging process. The experiment was conducted under a condition of a high temperature difference between the current circuit and the cover. The dielectric response was measured with the FDS (Frequency Dielectric Spectroscopy) and the SVM (Step Voltage Measurement) methods. The research has shown the correlation between the aging time and some parameters obtained with the FDS and SVM analysis.