Korean Journal of Clinical Laboratory Science (Mar 2021)

Study of Practical Method for International 10∼20 Electrode System

  • Sung-Hee Kim,
  • Ok-Kyoung Lee,
  • Dae Jin Kim

DOI
https://doi.org/10.15324/kjcls.2021.53.1.60
Journal volume & issue
Vol. 53, no. 1
pp. 60 – 67

Abstract

Read online

Electroencephalography (EEG) is used for the diagnosis of epilepsy and testing the brain function. Clinical technologists are responsible for recording EEG without artifacts in accordance with the international 10∼20 electrode system. Training on these techniques requires practical education. In the case of EEG, however, it is difficult for trainees to find the correct location of the electrode. Therefore, this study compared the time spent to locate the electrode attachment between traditional tape and the newly developed band. The time spent for sitting position patients using the band (196.7±61.8s) was 1084.3 s faster than the tape (1,281.0±457.4s) (P<0.001). Furthermore, the spend time spent for lying position patients using the band (200.2±49.3s) was 1217.7s faster than the tape (1417.9±482.3s) (P<0.001). Measurements using the band showed fewer differences due to various factors, such as position, practical experience, and gender. The newly developed band can locate the correct electrode attachment position quickly and efficiently, which has been a difficult problem in EEG practical education. In addition, this band is expected to be applied widely by new clinical technologists in the clinical field. Nevertheless, more study will be required to verify the accuracy of the location of the attaching electrode.