The Effects of Amofer Palm Oil Waste-based Complete Feed to Blood Profiles and Liver Function on Local Sheep

International Journal of Science and Engineering. 2012;3(1):17-21 DOI 10.12777/ijse.3.1.17-21

 

Journal Homepage

Journal Title: International Journal of Science and Engineering

ISSN: 2086-5023 (Print); 2302-5743 (Online)

Publisher: Diponegoro University

Society/Institution: Department of Chemical Engineering, Diponegoro University

LCC Subject Category: Technology: Technology (General) | Science: Science (General)

Country of publisher: Indonesia

Language of fulltext: English

Full-text formats available: PDF

 

AUTHORS

Hamdi Mayulu
S Sunarso
C. Imam Sutrisno
S Sumarsono

EDITORIAL INFORMATION

Peer review

Editorial Board

Instructions for authors

Time From Submission to Publication: 8 weeks

 

Abstract | Full Text

<p>Amoniation-Fermentation (amofer) technology should be conducted in order to improve the low quality of by product produced from palm oil plantations and mills (palm oil waste) which is used for constituent of feed ingredients in complete feed (CF). This technology also reforms the feed material into edible form. Before broadly applicable, it must be ensured that the feed does not have toxic effects on livestock. This research was peformed to evaluate the effects of amofer palm oil waste-based CF to blood profile and liver function on local sheep. Completely Randomly Design (CRD) was used with 4 treaments and 4 replications. The observed variables were the levels of hemoglobin, hematocrit, blood glucose, ALT and AST was analyzed by ANOVA. The average value of blood glucose levels at T<sub>1</sub>= 80.68 mg/dl, T<sub>2</sub>=79.08 mg/dl, T<sub>3</sub>=81.18 mg/dl and T<sub>4</sub>=73.70 mg/dl. The average value of hemoglobin levels at T<sub>1</sub>=10.80 g/dl, T<sub>2</sub>=10.30 g/dl, T<sub>3</sub>=11.23 g/dl and T<sub>4</sub>=10.25 g/dl. The average value of hematocrit levels at T<sub>1</sub>=31.00%, T<sub>2</sub>=31.00%, T<sub>3</sub>=33.75% and T<sub>4</sub>=30%. The average value of ALT levels at T<sub>1</sub>=17.90 ml, T<sub>2</sub>=13.83 ml, T<sub>3</sub>=18.75 ml and, T<sub>4</sub>=13.40 ml. The average value of AST level at T<sub>1</sub>=106.20 ml, T<sub>2</sub>=88.98 ml, T<sub>3</sub>=104.40 ml and T<sub>4</sub>=91.25 ml. There was no significant difference among four treatments (p&gt;0.05). The administration CF did not cause hematological disorders which showed by the blood profiles and liver function were in normal range, so that suggested the CF was appropriate and safe for local sheep.</p> <p>[<em>Keywords&ndash;&ndash;amofer, complete feed, hemoglobin, hematocrit, glucose, liver function</em>]</p>