Brazilian Journal of Cardiovascular Surgery (Jan 1998)

Enxertos valvares aórticos homólogos: estudo experimental em cães

  • Rui Manoel Sequeira de ALMEIDA,
  • Danton R. da Rocha LOURES,
  • Hélcio GIFFHORN,
  • Katia PIFFER,
  • Ana Cláudia Araújo dos SANTOS,
  • Maureen Aparecida de OLIVEIRA,
  • Edison José RIBEIRO,
  • Maria João Amorim FERREIRA

DOI
https://doi.org/10.1590/S0102-76381998000100009
Journal volume & issue
Vol. 13, no. 1
p. 48

Abstract

Read online

Vinte cães foram divididos em dois grupos de dez, sendo um o grupo doador (Grupo 1) e o outro, o receptor (Grupo 2). Todos os animais do grupo 1 foram submetidos a uma toracotomia mediana e sacrificados, para a retirada do coração e da valva aórtica; os cães do grupo 2 foram submetidos a uma laparotomia mediana para o implante das valvas aórticas homólogas na aorta abdominal infra-renal. O peso médio dos cães do grupo 1 era de 5,5 ± 1,7 kg e o diâmetro médio da aorta descendente de 11,8 ± 1,4 mm. No grupo 2 o peso médio era de 11,9 ± 2,3 kg e o diâmetro da aorta abdominal, de 8,8 ± 1,2 mm. A operação no grupo 2 teve como intercorrência a lesão do conduto linfático, em 4 casos, sendo o tempo médio de isquemia, durante o implante do enxerto homólogo, de 37,6 ± 13,3 min. Os animais foram acompanhados por um período de trinta dias, à exceção de 3. Um cão faleceu no décimo dia de pós-operatório por infarto da artéria mesentérica inferior; um segundo foi sacrificado no décimo quarto dia, por apresentar deiscência parcial da ferida cirúrgica, e o terceiro se evadiu no vigésimo quinto dia de pós-operatório. Dois animais apresentaram deiscência da incisão cirúrgica, levando a uma morbidade de 20%. No trigésimo dia, todos os animais sobreviventes foram submetidos a nova laparotomia, quando foram analisados as aderências da cavidade abdominal e o hematoma em torno do enxerto homólogo, e foram aferidas e registradas as pressões proximal e distal ao enxerto valvar (gradiente médio de 25 mmHg). Após o sacrifício do animal, os enxertos foram explantados para a análise das válvulas que eram normais, à excepção de dois, que apresentavam trombos e retração com fibrose, porém, sem significação clínica. Conclui-se que o modelo é viável para estudos futuros sobre valvas aórticas homólogas.The aim of this research was to develop an experimental model, with dogs, to study homologous aortic valve grafts. A group of twenty randomly selected dogs was divided into two subgroups of tem, being Group I the donor group and Group II the recipient group. The surgical approach to the animals of Group I was through a median thoracotomy through which the heart was explanted. The homograft aortic valve was trimmed and prepared. The technical procedures are described step by step. All the dogs from Group II had a median laparotomy performed and the homograft was immediately implanted in the abdominal aorta below the emergence of both renal arteries. The median weight of Group I dogs was 5.5 ± 1.7 kg and 11.9 ± 2.3 kg for Group II. The abdominal aorta's diameter was 8.8 ± 1.2 mm and the one of the homograft valve was 11.8 ± 1.4 mm. The only problem during surgery was the injury of the lymphatic ducts in four cases, with no consequences after its ligation. The mean period of occlusion was 37.6 ± 13.3 minutes. One animal died ten days after surgery due to inferior mesenteric infarction; a second one was sacrificed 14 days after surgery due to a serious infection of the surgical wound; a third animal escaped from the bioterium 25 days after surgery. All the remaining dogs were submitted to a new laparotomy after 30 days. The abdominal cavity was analyzed for adhesions and grafts' haematoma and the aortic pressures proximal and distally to the graft registered (mean gradient was 2.5 mm/Hg). The cusps and the graft were satisfactory, except in two cases, due to partial fixation of one of the cusps; thrombi appeared on all the other two sinuses of Valsalva. Concluding it was felt that this experimental model is compatible, for future studies, of aortic valve homologous grafts.

Keywords