Microbiology Spectrum (Apr 2025)

The development and validation of a microneutralization assay for the detection and quantification of anti-yellow fever virus antibodies in human serum

  • Katherine Fries,
  • Ping Luo,
  • Rebekah Baldwin,
  • Raechel Goldberg,
  • Ivan Ordonez,
  • Lingyi Zheng,
  • James Huleatt,
  • Louis Devlin

DOI
https://doi.org/10.1128/spectrum.03348-24
Journal volume & issue
Vol. 13, no. 4

Abstract

Read online

ABSTRACT The plaque reduction neutralization test (PRNT) has been used widely for the detection and quantitation of yellow fever (YF) virus-neutralizing antibodies in human serum; however, it is labor-intensive and challenging to adapt to high-throughput clinical testing needed for vaccine licensure. Here, we describe the development and validation of a new Vero cell-based YF microneutralization (MN) assay, with immunostaining readout, for the detection and quantification of YF virus-neutralizing antibodies in human serum. Comparison of neutralizing antibody titers measured with the YF MN assay versus the historical YF PRNT, based on a 50% reduction in plaque counts (PRNT50), demonstrated 100% serostatus agreement at a titer of 10 (1/dil) in participants with a history of YF vaccination. For validation, intra-assay precision (repeatability), intermediate precision, dilutional accuracy, linearity, specificity, upper limit of quantitation (ULOQ), and lower limit of quantitation (LLOQ) were assessed. The YF MN assay demonstrated suitable intra-assay precision (repeatability) and intermediate precision of 36% and 54%, respectively, with an ULOQ of 10,240. At the lower end of detection, repeatability and intermediate precision were 38% and 41%, respectively, with a LLOQ of 10 (1/dil). Suitable dilutional accuracy, linearity, and specificity across orthoflaviviruses (dengue virus, Japanese encephalitis virus, and Zika virus) and serum matrices (hemolytic, lipemic, and icteric) were also demonstrated. Overall, these promising results led the Center for Biologics Evaluation and Research to confirm the suitability of the validated YF MN assay for the detection and quantification of YF virus-neutralizing antibodies.IMPORTANCEWith increased globalization and shifting climate patterns, yellow fever (YF) is re-emerging as a global threat. At present, vaccination remains the most effective prevention strategy. This study describes the development and validation of a new YF microneutralization (MN) assay for the detection and quantification of YF virus-neutralizing antibodies in human serum that offers increased throughput compared with the current standard assay. Overall, the YF MN assay demonstrated acceptable intra-assay precision (repeatability), intermediate precision, dilutional accuracy, linearity, and specificity and is suitable for the detection of YF virus-neutralizing antibodies. Further, the Center for Biologics Evaluation and Research (CBER) supports the use of the YF MN assay in the licensure of candidate YF vaccines.

Keywords