Actuators (Jan 2025)

Analysis of Collision Types in Collaborative Robots Using Mechanism Actuated by Pneumatic Artificial Muscle

  • Dávid Kóczi,
  • József Sárosi

DOI
https://doi.org/10.3390/act14010022
Journal volume & issue
Vol. 14, no. 1
p. 22

Abstract

Read online

In the safety technology of collaborative robots, standards differentiate between various collision types, the identification and differentiation of which are essential for ensuring safe operation. The objective of this paper is to develop and test a mechanism actuated by artificial muscle to examine the detection of these profiles in different collision scenarios. The ISO 15066 standard distinguishes between two types of collisions: quasi-static and transient. Using a simplified model, experiments were conducted to evaluate whether sensors could identify collision types accurately. The results demonstrate the feasibility of identifying collision types through sensor data. The findings have the potential to enhance the safety of collaborative robots.

Keywords