Engineering Reports (Sep 2022)

Prediction of effective vibration condition under air void reduction using mortar rheological constant

  • Tomoaki Kisaku,
  • Yuki Yoshida,
  • Kaho Muto,
  • Takashi Kurosawa,
  • Yuji Ito,
  • Chikako Fujiyama

DOI
https://doi.org/10.1002/eng2.12484
Journal volume & issue
Vol. 4, no. 9
pp. n/a – n/a

Abstract

Read online

Abstract Air voids remaining on the concrete surface are detrimental to the durability. Surface voids also affect the esthetics of concrete structures. In this study, the method of reducing the surface voids caused by entrapped air of fresh concrete was verified using 122 cases of vibration box tests with different materials, mix proportions, vibration frequencies, and amplitudes. The surface void area ratio (SVAR) decreased when the acceleration of the vibration box was increased regardless of the type of concrete. The relationship between SVAR and acceleration can be expressed through a power function. However, a segregation was observed in medium‐fluidity concrete when the acceleration exceeded 4.0 Gal (hereinafter referred to as G). In addition, the SVAR correlated with the mortar rheological constant was measured using a steel ball pull‐up test. An equation using mortar rheological constants, which can be estimated using a concrete slump, was proposed to predict the SVAR‐acceleration relationship.

Keywords