BMC Musculoskeletal Disorders (Aug 2021)
Translation, cross-cultural adaptation, reliability and construct validity of the Dutch Oxford Knee Score – Activity and Participation Questionnaire
Abstract
Abstract Background Patients undergoing total knee arthroplasty (TKA) tend to be younger and tend to receive TKA at an earlier stage compared to 20 years ago. The Oxford Knee Score – Activity and Participation (OKS-APQ) questionnaire evaluates higher levels of activity and participation, reflecting activity patterns of younger or more active people. The purpose of this study was to translate the OKS-APQ questionnaire into Dutch, and to evaluate its measurement properties in pre- and postoperative TKA patients. Methods The OKS-APQ was translated and adapted according to the forward–backward translation multi step approach and tested for clinimetric quality. Floor and ceiling effects, structural validity, construct validity, internal consistency and test–retest reliability were evaluated using COSMIN quality criteria. The OKS-APQ, the Oxford Knee Score (OKS), the Short Form-36 (SF-36), a Visual Analogue Scale (VAS) for pain and the Forgotten Joint Score (FJS) were assessed in 131 patients (72 preoperative and 59 postoperative TKA patients), and the OKS-APQ was administered twice in 50 patients (12 preoperative and 38 postoperative TKA patients), after an interval of minimal 2 weeks. Results Floor effects were observed in preoperative patients. Confirmatory factor analyses (CFA) indicated a good fit of a 1-factor model by the following indices: (Comparative Fit Index (CFI): 0.97, Tucker-Lewis Index (TLI): 0.96 and Standardized Root Mean Square Residual (SRMR): 0.03). Construct validity was supported as > 75% of the hypotheses were confirmed. Internal consistency (Cronbach α’s from 0.81 to 0.95) was good in the pooled and separate pre- and postoperative samples and test–retest reliability (Intraclass Correlation Coefficients (ICCs) from 0.63 – 0.85) were good in postoperative patients and moderate in preoperative patients. The standard Error of Measurements (SEMs) ranged from 8.5 – 12.2 and the Smallest Detectable Changes in individuals (SDCind) ranged from 23.5 – 34.0 (on a scale from 0 to 100). Conclusions Preliminary findings suggest that the Dutch version of the OKS-APQ is reliable and valid for a Dutch postoperative TKA patient sample. However, in a preoperative TKA sample, the OKS-APQ seems less suitable, because of floor effects and lower test–retest reliability. The Dutch version of the OKS-APQ can be used alongside the OKS to discriminate among levels of activity and participation in postoperative patients.
Keywords