Chemical Industry and Chemical Engineering Quarterly (Sep 2008)

THE EFFECT OF THE SLUDGE RECYCLE RATIO IN AN ACTIVATED SLUDGE SYSTEM FOR THE TREATMENT OF AMOL'S INDUSTRIAL PARK WASTEWATER

  • BAHAR HOSSEINI,
  • GHASEM NAJAFPOUR DARZI,
  • MAEDEH SADEGHPOUR,
  • MOSTAFA ASADI

Journal volume & issue
Vol. 14, no. 3
pp. 173 – 180

Abstract

Read online

An activated sludge aeration tank and a sedimentation basin were used to treat Amol’s industrial park effluents originating from all industrial units. A continuous system was implemented and the kinetic parameters were measured.The parameters such as rate constant, substrate utilization rate constant, yield and decay coefficient were 2.12 d-1, 232.4 mg l-1, 0.33 g/g of substrate and 0.096 d−1, respectively. The hydraulic retention times (HRT) were in the range of 9 to 27 h. The sludge recycle ratios in the range from 0.3 to 1 were considered. The COD removal, SVI and DO were determined and the optimal values were obtained. It was observed that at HRT of 16 h and the sludge recycle ratio of 0.85, the COD removal and SVI were 95 and 85 %, respectively. The sludge recycle ratio greater than 0.85 had no significant effect on the COD removal.