Arquivos Brasileiros de Cardiologia (Sep 2008)

Índice de dissincronia ventricular: comparação com a fração de ejeção bidimensional e tridimensional Ventricular dyssynchrony index: comparison with two-dimensional and three-dimensional ejection fraction

  • Marcelo L. C. Vieira,
  • Alexandre F. Cury,
  • Naccarato Gustavo,
  • Wercules A. Oliveira,
  • Cláudia G. Monaco,
  • Adriana Cordovil,
  • Ana C. T. Rodrigues,
  • Edgar B. Lira Filho,
  • Cláudio H. Fischer,
  • Samira S. Morhy

DOI
https://doi.org/10.1590/S0066-782X2008001500004
Journal volume & issue
Vol. 91, no. 3
pp. 156 – 162

Abstract

Read online

FUNDAMENTO: O acoplamento eletromecânico (sincronia) do ventrículo esquerdo (VE) tem importância na análise da performance sistólica, especialmente para a indicação da terapia de ressincronização cardíaca em pacientes com ICC avançada. OBJETIVO: Comparar a sincronia do VE analisada com ecocardiograma (eco) tridimensional (3D) em tempo real com medidas de FEVE obtidas com ECO 2D e 3D. MÉTODOS: Estudo prospectivo de 92 indivíduos (56 homens, 47±10 anos), 60 com anatomia cardíaca (eco) e ECG normais (Grupo N), 32 com cardiomiopatia dilatada (Grupo CMD). Com o emprego do ECO 3D foram aferidos FEVE, volumes e índice de dissincronia (ID)% para 16 segmentos do VE; com o ECO 2D foram medidos FEVE (método de Simpson) e volumes sistólico e diastólico do VE. Análise estatística: coeficiente de correlação (Pearson), 95% IC, teste de regressão linear, teste de Bland & Altman, pBACKGORUND: Left ventricular (LV) electromechanical coupling (synchrony) is important in the analysis of the systolic performance, especially for the indication of cardiac resynchronization therapy in patients with advanced CHF. OBJECTIVE: To compare LV synchrony as analyzed by real-time three-dimensional (3D) echocardiography (ECHO) with LVEF measurements as obtained with 2D and 3D ECHO. METHODS: Prospective study of 92 individuals (56 men, 47 ± 10 years of age), of which 60 had normal heart structure (ECHO) and ECG (N group), and 32 had dilated cardiomyopathy (DCM group). Using 3D ECHO, LVEF, volumes and dyssynchrony index (%DI) for 16 LV segments were measured. Using 2D ECHO, LVEF (Simpson's method), and LV systolic and diastolic volumes were measured. Statistical analysis: Pearson's correlation coefficient, 95% CI, linear regression model, Bland & Altman analysis, p<0.05. RESULTS: %DI ranged from 0.2900 to 28.1000 (5.2014±6.3281), 3D LVEF ranged from 0.17 to 0.81 (0.52±0.17); and 2D LVEF ranged from 0.3 to 0.69 (0.49±0.11). The correlation between DI and 3D LVEF was (r): -0.7432, p<0.0001, CI: -0.8227 to -0.6350, the linear relation between DI (x) and 3D LVEF (y) was y = 19.8124 + (-27.9578) x, p<0.0001. The correlation between DI and 2D LVEF was (r): -0.7012, p<0.0001, CI: -0.7923 to -0.5797. CONCLUSION: In this case series, a good negative correlation was observed between LV electromechanical three-dimensional systolic coupling and LVEF as measured by echocardiography (3D and 2D).

Keywords