Archives of Metallurgy and Materials (Dec 2017)

Similarity of Ferrosilicon Submerged Arc Furnaces With Different Geometrical Parameters

  • Machulec B.,
  • Gil S.,
  • Bialik W.

DOI
https://doi.org/10.1515/amm-2017-0344
Journal volume & issue
Vol. 62, no. 4
pp. 2343 – 2347

Abstract

Read online

In order to determine reasons of unsatisfactory production output regarding one of the 12 MVA furnaces, a comparative analysis with a furnace of higher power that showed a markedly better production output was performed. For comparison of ferrosilicon furnaces with different geometrical parameters and transformer powers, the theory of physical similarity was applied. Geometrical, electrical and thermal parameters of the reaction zones are included in the comparative analysis. For furnaces with different geometrical parameters, it is important to ensure the same temperature conditions of the reaction zones. Due to diverse mechanisms of heat generation, different criteria for determination of thermal and electrical similarity for the upper and lower reaction zones were assumed contrary to other publications. The parameter c3 (Westly) was assumed the similarity criterion for the upper furnace zones where heat is generated as a result of resistive heating while the parameter J1 (Jaccard) was assumed the similarity criterion for the lower furnace zones where heat is generated due to arc radiation.

Keywords