Sensors (Jul 2022)

Four-Line C<sub>2</sub>*/CH* Optical Sensor for Chemiluminescence Based Imaging of Flame Stoichiometry

  • Michael E. Tonarely,
  • Tommy Genova,
  • Anthony J. Morales,
  • Daniel Micka,
  • Darin Knaus,
  • Kareem A. Ahmed

DOI
https://doi.org/10.3390/s22155665
Journal volume & issue
Vol. 22, no. 15
p. 5665

Abstract

Read online

In the present work, an optical sensor was developed and calibrated for the purpose of non-intrusive equivalence ratio measurements in combustion systems. The sensor incorporates a unique four-line, single-sensor chemiluminescence imaging-based approach, which relies on the ratio of C2* and CH* radical-species intensities to obtain measurements of equivalence ratios. The advantage of the four-line sensor is the use of additional filtering to mitigate broadband luminescence signals, and its improvements over conventional two-line chemiluminescence diagnostics are discussed. The sensor was calibrated using a premixed bluff-body jet burner with a propane–air flame operating over a wide range of equivalence ratios. The results showed that the four-line processing technique improved the signal-to-noise ratio of the chemiluminescence images for all test cases. Calibrations of C2*/CH* intensity ratio to equivalence ratio were developed for both the four-line and two-line techniques. The calibrations were then used to create maps of local equivalence ratios in the flame-holding region. The maps revealed a non-uniform field of equivalence ratios due to the nature of the radical-species intensity profiles within the flame. Therefore, special consideration is required for calibration in order to accurately quantify equivalence ratios and apply these to diffusion flames.