Guoji Yanke Zazhi (Sep 2013)

Effect of Ahmed valve implantation on late neovascular glaucoma

  • Ping-An Mao,
  • Yan-Wen Jia,
  • Yang Xie,
  • Guo-Hua Lu

DOI
https://doi.org/10.3980/j.issn.1672-5123.2013.09.24
Journal volume & issue
Vol. 13, no. 9
pp. 1820 – 1821

Abstract

Read online

AIM: To discuss the effect and safety of Ahmed valve implantation in late neovascular glaucoma. METHODS: The Ahmed glaucoma valve were implanted in 41 eyes(41 cases)with late neovascular glaucoma, the follow-up was 12 months on average, intraocular pressure was recorded at 1 day, 1 week, 1 month, 3, 6, 12 months respectively after operation and compared with that before operation, at the same time, the complications and treatment were analyzed.RESULTS: The mean intraocular pressure before operation, 1 day, 1 week, 1 month, 3, 6, 12 months after operation was 59.83±5.53, 19.27±8.19, 19.69±6.86, 20.67±6.73, 21.05±6.93, 21.49±7.42, 22.14±8.08mmHg, the mean intraocular pressure before operation was higher than that after operation and the difference was obvious in statistics. Major complications included hyphema, low intraocular pressure early postoperation, shallow anterior chamber, obstruction of the tube, the plate wrapped or exposed.CONCLUSION: Ahmed valve implantation is an effective method to treatlate neovascular glaucoma.

Keywords