Química Nova (Jan 2009)

Optimization of the use of carbon paste electrodes (CPE) for electrochemical study of the chalcopyrite

  • Daniela G. Horta,
  • Denise Bevilaqua,
  • Heloísa A. Acciari,
  • Oswaldo Garcia Júnior,
  • Assis V. Benedetti

DOI
https://doi.org/10.1590/S0100-40422009000700010
Journal volume & issue
Vol. 32, no. 7
pp. 1734 – 1738

Abstract

Read online

The use of carbon paste electrodes (CPE) of mineral sulfides can be useful for electrochemical studies to overcome problems by using massive ones. Using CPE-chalcopyrite some variables were electrochemically evaluated. These variables were: (i) the atmosphere of preparation (air or argon) of CPE and elapsed time till its use; (ii) scan rate for voltammetric measurements and (iii) chalcopyrite concentration in the CPE. Based on cyclic voltammetry, open-circuit potential and electrochemical impedance results the recommendations are: oxygen-free atmosphere to prepare and kept the CPE until around two ours, scan rates from 10 to 40 mV s-1, and chalcopyrite concentrations > 20%.

Keywords