The Ultrasound Journal (Dec 2023)
Additional predictive value of optic nerve sheath diameter for neurological prognosis after cardiac arrest: a prospective cohort study
Abstract
Abstract Background The goal is to estimate the additional value of ultrasonographic optic nerve sheath diameter (ONSD) measurement on days 1–3, on top of electroencephalography (EEG), pupillary light reflexes (PLR), and somatosensory evoked potentials (SSEP), for neurological outcome prediction of comatose cardiac arrest patients. We performed a prospective longitudinal cohort study in adult comatose patients after cardiac arrest. ONSD was measured on days 1–3 using ultrasound. Continuous EEG, PLR, and SSEP were acquired as standard care. Poor outcome was defined as cerebral performance categories 3–5 at 3–6 months. Logistic regression models were created for outcome prediction based on the established predictors with and without ONSD. Additional predictive value was assessed by increase in sensitivity for poor (at 100% specificity) and good outcome (at 90% specificity). Results We included 100 patients, 54 with poor outcome. Mean ONSD did not differ significantly between patients with good and poor outcome. Sensitivity for predicting poor outcome increased by adding ONSD to EEG and SSEP from 25% to 41% in all patients and from 27% to 50% after exclusion of patients with non-neurological death. Conclusions ONSD on days 1–3 after cardiac arrest holds potential to add to neurological outcome prediction. Trial registration: clinicaltrials.gov, NCT04084054. Registered 10 September 2019, https://www.clinicaltrials.gov/study/NCT04084054 .
Keywords