Journal of Physiological Anthropology (Oct 2023)

Multipoint surface electromyography measurement using bull’s-eye electrodes for wide-area topographic analysis

  • Megumi Shimura,
  • Akihiko Mizumoto,
  • Yali Xia,
  • Yoshihiro Shimomura

DOI
https://doi.org/10.1186/s40101-023-00342-3
Journal volume & issue
Vol. 42, no. 1
pp. 1 – 6

Abstract

Read online

Abstract Background Surface electromyography (sEMG) is primarily used to analyze individual and neighboring muscle activity. However, using a broader approach can enable simultaneous measurement of multiple muscles, which is essential for understanding muscular coordination. Using the “bull’s-eye electrode,” which allows bipolar derivation without directional dependence, enables wide-area multipoint sEMG measurements. This study aims to establish a multipoint measurement system and demonstrate its effectiveness and evaluates forearm fatigue and created topographic maps during a grasping task. Methods Nine healthy adults with no recent arm injuries or illnesses participated in this study. They performed grasping tasks using their dominant hand, while bull’s-eye electrodes recorded their muscle activity. To validate the effectiveness of the system, we calculated the root mean squares of muscle activity and entropy, an indicator of muscle activity distribution, and compared them over time. Results The entropy analysis demonstrated a significant time-course effect with increased entropy over time, suggesting increased forearm muscle uniformity, which is possibly indicative of fatigue. Topographic maps visually displayed muscle activity, revealing notable intersubject variations. Discussion Bull’s-eye electrodes facilitated the capture of nine homogeneous muscle activity points, enabling the creation of topographic images. The entropy increased progressively, suggesting an adaptive muscle coordination response to fatigue. Despite some limitations, such as inadequate measurement of the forearm muscles’ belly, the system is an unconventional measurement method. Conclusion This study established a robust system for wide-area multipoint sEMG measurements using a bull’s-eye electrode setup. This system effectively evaluates muscle fatigue and provides a comprehensive topographic view of muscle activity. These results mark a significant step towards developing a future multichannel sEMG system with enhanced measurement points and improved wearability. Trial registration This study was approved by the Ethics Committee of Chiba University Graduate School of Engineering (acceptance number: R4-12, Acceptance date: November 04, 2022).

Keywords