Abstract

Read online

The behavior of corona discharge was investigated in wire–cylinder electrodes under the effect of a crossed magnetic field. Townsend’s formula was used commonly with a modified empirical formula to evaluate the different parameters of corona discharge in positive and negative discharge. By using a least-squares fitting, the dimensional constants A, K, and the exponent n displayed a significant dependence on the applied magnetic field. An improvement of pre-breakdown has been achieved by using a crossed magnetic field. For both polarities, while the magnetic field is present, breakdown voltage VB and corona inception voltage V0 increased, whereas the corona current decreases. In addition, the corona inception voltage was greater in positive corona in the absence of a magnetic field, while the opposite occurred regarding the crossed magnetic field. Furthermore, the breakdown streamer demonstrated significant triggering in the negative corona by applying the magnetic field.