Journal of Pharmaceutical Analysis (Apr 2013)

Luminol–K3Fe(CN)6 chemiluminescence system for the determination of glipizide

  • Xin Chen,
  • Li-Li Xing,
  • Yu-Hai Tang,
  • Guang-Bin Zhang

Journal volume & issue
Vol. 3, no. 2
pp. 127 – 131

Abstract

Read online

A rapid and sensitive flow-injection chemiluminescence (CL) method for the determination of glipizide was developed on the basis of finding that glipizide can enhance the CL intensity of the luminol–K3Fe(CN)6 system. In optimum condition, the increased CL intensity was directly proportional to the concentration of glipizide in the range from 4.0×10−8 g/mL to 1.0×10−6 g/mL and the detection limit was 1.0×10−8 g/mL glipizide. The relative standard deviation (RSD) of the developed method was 2.1% with 11 repeated measurements of 1.0×10−7 g/mL glipizide. The developed method has been successfully applied to the analysis of glipizide in its pharmaceutical preparations. Keywords: Luminol–K3Fe(CN)6, Glipizide, Flow injection, Chemiluminescence