Eye and Vision (Sep 2024)
Efficacy of orthokeratology lens with the modified small treatment zone on myopia progression and visual quality: a randomized clinical trial
Abstract
Abstract Background To evaluate the long-term effectiveness of orthokeratology (ortho-K) lenses with small treatment zone (STZ) or conventional treatment zone (CTZ) in controlling axial elongation in children with myopia as well as the impact on visual quality. We also sought to determine the effect of retinal visual signal quality on axial elongation. Methods This is a prospective randomized controlled study. A total of 140 participants (age ranging from 8 to 12 years) were randomly assigned to wear either STZ or CTZ ortho-K lenses. STZ ortho-K lenses design was achieved by changing the depth of reverse zone and the sagitta height of the optical zone. Using the IOL-Master 500, axial length (AL) was measured at baseline and after 6, 12 and 18 months of ortho-K treatment. Spherical aberration (SA) and corneal topographic parameters were obtained by the Pentacam anterior segment analyzer at baseline and the 1-month follow-up visit, and optical qualities were assessed by optical quality analysis system-II (OQAS-II) at baseline and after 1 month of lens wearing. Optical quality parameters mainly included the modulation transfer function (MTF) cutoff, Strehl ratio (SR), objective scattering index (OSI), and predicted visual acuity (PVA). Results A total of 131 participants completed the study, including 68 in the STZ group and 63 in the CTZ group. The STZ group had significantly reduced AL elongation compared to the CTZ group after treatment (12 months: 0.07 ± 0.11 mm vs. 0.14 ± 0.12 mm, P = 0.002; 18 months: 0.17 ± 0.15 mm vs. 0.26 ± 0.16 mm, P = 0.002). The topography in the STZ group showed a smaller treatment zone (TZ) diameter (2.50 ± 0.23 mm vs. 2.77 ± 0.18 mm, P < 0.001), a wider defocus ring width (2.45 ± 0.28 mm vs. 2.30 ± 0.30 mm, P = 0.006), and larger values of total amount of defocus (119.38 ± 63.71 D·mm2 vs. 91.40 ± 40.83 D·mm2, P = 0.003) and total SA (0.37 ± 0.25 μm vs. 0.25 ± 0.29 μm, P = 0.015), compared with the CTZ group. Objective visual quality decreased in both groups (P < 0.001). This was evidenced by a greater decrease in MTF cutoff (− 14.24 ± 10.48 vs. − 10.74 ± 9.46, P = 0.047) and SR values (− 0.09 ± 0.07 vs. − 0.06 ± 0.07, P = 0.026), and an increase in OSI value (0.84 ± 0.72 vs. 0.58 ± 0.53, P = 0.019). PVA9% decreased significantly in the STZ group but not the CTZ group. A statistically significant negative correlation was found between the changes in total SA and MTF cutoff values (r = − 0.202, P = 0.025). AL changes were associated with sex, change of MTF cutoff value, increment of total SA and TZ area. Conclusions Compared with CTZ ortho-K lenses, STZ ortho-K lenses significantly inhibited axial elongation in children with myopia while moderately reducing their objective visual quality. Axial elongation was affected by retinal visual quality, and it may be a possible mechanism for ortho-K slowing myopia progression. Trial registration This trial is registered at Chinese Clinical Trial Registry on November 5, 2019 with trial registration number: ChiCTR1900027218. https://www.chictr.org.cn/showproj.html?proj=45380
Keywords