Xibei Gongye Daxue Xuebao (Feb 2020)

Optimal Design and Application of Gas Analysis System

  • ,
  • ,
  • ,

DOI
https://doi.org/10.1051/jnwpu/20203810104
Journal volume & issue
Vol. 38, no. 1
pp. 104 – 113

Abstract

Read online

To accurately measure the performance parameters of an aero-engine combustor under high-temperature and high-pressure environment, such as outlet temperature, combustion efficiency and pollutant emission, the optimal design of the existing gas sampling and analysis system was carried out, the data post-processing method was corrected, and the full-component enthalpy conservation method suitable for calculating combustor outlet temperature was established. A lean direct injection and low-pollution combustor was used to evaluate the performance and application of its gas analysis system and its data post-processing method. The investigation results indicate that the optimized gas analysis system meets the International Civil Aviation Organization's pollutant emission measurement requirements and that it has a fast response and a high data quality. The comparison of the measurement results of the gas analysis system with those of the traditional measurement methods shows that the gas analysis system has a more accurate measurement, a wider condition range and a better stability, thus accurately evaluating the outlet temperature, combustion efficiency and emission characteristics of a gas turbine combustor.

Keywords