Sports (Sep 2023)

Accelerometer-Derived Intensity Thresholds Are Equivalent to Standard Ventilatory Thresholds in Incremental Running Exercise

  • Matthias Schützenhöfer,
  • Philipp Birnbaumer,
  • Peter Hofmann

DOI
https://doi.org/10.3390/sports11090171
Journal volume & issue
Vol. 11, no. 9
p. 171

Abstract

Read online

Accelerometer cut-points are commonly used to prescribe the amount of physical activity, but this approach includes no individual performance measures. As running kinetics change with intensity, acceleration measurements may provide more individual information. Therefore, the aim was to determine two intensity thresholds from accelerometer measures. A total of 33 participants performed a maximal incremental running test with spirometric and acceleration (Axivity AX3) measures at the left and right tibia. Ventilatory equivalents (VE/VO2, VE/VCO2) were used to determine a first and second ventilatory threshold (VT1/VT2). A first and second accelerometer threshold (ACT1/ACT2) were determined within the same regions of interest from vector magnitude (|v| = √(ax2 + ay2 + az2). Accelerometer data from the tibia presented a three-phase increase with increasing speed. Speed at VT1/VT2 (7.82 ± 0.39/10.91 ± 0.87 km/h) was slightly but significantly lower compared to the speed at ACT1/ACT2 from the left (7.71 ± 0.35/10.62 ± 0.72 km/h) and right leg (7.79 ± 0.33/10.74 ± 0.77 km/h). Correlation analysis revealed a strong relationship between speed at thresholds determined from spriometric data or accelerations (r = 0.98; p < 0.001). It is therefore possible to determine accelerometer thresholds from tibia placement during a maximal incremental running test comparable to standard ventilatory thresholds.

Keywords