Buildings (Jun 2022)

Experimental Investigations of the Behavior of Stiffened Perforated Cold-Formed Steel Sections Subjected to Axial Compression

  • Fattouh M. F. Shaker,
  • Zekriat Mamdooh,
  • Ahmed Deifalla,
  • Mohamed M. Yehia

DOI
https://doi.org/10.3390/buildings12060812
Journal volume & issue
Vol. 12, no. 6
p. 812

Abstract

Read online

Cold-formed steel sections are becoming popular for different steel structures, because they have a high resistance against different straining actions, with a minimal weight compared with hard steel sections. Recently, perforated cold-formed steel (PCFS) sections have been used in many applications, such as perforated upright storage racks. Experimental research into the behavior of steel storage rack uprights subjected to axial compression is presented in this paper. First, tensile tests determined the material qualities of the cold-formed steel uprights. Then, seventeen perforated specimens were examined under axial compression, with five different cross-sections, three different web heights and thicknesses, and varying lengths. The study’s goals were to find out how perforations affect the performance and failure mode of steel storage rack uprights, to discuss the interaction of distortional and global buckling, and to verify the accuracy of using the direct strength method (DSM) for predicting the ultimate strength before failure in buckling interactions for perforated uprights. It was found that the failure modes of perforated specimens with stiffeners generally cannot be well predicted using the direct strength method. However, when the modifications proposed by Xianzhong Zhao et al. are used, the accuracy is acceptable.