Abstract

Read online

Acrylic materials are used daily for the production of mobile dental restorations and orthodontic appliances. The presence of residual monomer, as a product of incomplete polymerisation of material, results in more porous structure of the material, which greatly reduces the mechanical and physical quality of the acrylic restorations and increases the absorption of liquids. The aim of this study was to examine the water absorption of different types of resin material. In the study it was assumed that the cold polymerized acrylates show a greater potential for absorbing fluid from the environment in relation to the hot polymerized acrylic. The study included two hot and two cold polymerized acrylates, and cold polymerized acrylate impregnated with aesthetic pearls. In order to determine the degree of water absorption, the mass of the samples was measured before and after one day, seven days and thirty days of immersion in a water bath of body temperature. The tested hot and cold polymerized acrylates after immersion in water bath showed standard values of water absorption. The degree of water absorption was not significantly influenced by the type and manner of polymerisation. Water absorption values were significantly higher after seven days and thirty days of water storage relative to the observational period of one day.

Keywords