Nuclear Technology and Radiation Protection (Jan 2002)

Calibration of the simulation model of the VINCY cyclotron magnet

  • Ćirković Saša,
  • Ristić-Đurović Jasna,
  • Vorozhtsov Alexey S.,
  • Vorozhtsov Serguei B.

DOI
https://doi.org/10.2298/NTRP0202013C
Journal volume & issue
Vol. 17, no. 1-2
pp. 13 – 18

Abstract

Read online

The MERMAID program will be used to isochronise the nominal magnetic field of the VINCY Cyclotron. This program simulates the response, i. e. calculates the magnetic field, of a previously defined model of a magnet. The accuracy of 3D field calculation depends on the density of the grid points in the simulation model grid. The size of the VINCY Cyclotron and the maximum number of grid points in the XY plane limited by MERMAID define the maximumobtainable accuracy of field calculations. Comparisons of the field simulated with maximum obtainable accuracy with the magnetic field measured in the first phase of the VINCY Cyclotron magnetic field measurements campaign has shown that the difference between these two fields is not as small as required. Further decrease of the difference between these fields is obtained by the simulation model calibration, i. e. by adjusting the current through the main coils in the simulation model.

Keywords