AIP Advances (Jan 2014)

Calculation and measurement of a neutral air flow velocity impacting a high voltage capacitor with asymmetrical electrodes

  • M. Malík,
  • J. Primas,
  • V. Kopecký,
  • M. Svoboda

DOI
https://doi.org/10.1063/1.4864181
Journal volume & issue
Vol. 4, no. 1
pp. 017137 – 017137-7

Abstract

Read online

This paper deals with the effects surrounding phenomenon of a mechanical force generated on a high voltage asymmetrical capacitor (the so called Biefeld-Brown effect). A method to measure this force is described and a formula to calculate its value is also given. Based on this the authors derive a formula characterising the neutral air flow velocity impacting an asymmetrical capacitor connected to high voltage. This air flow under normal circumstances lessens the generated force. In the following part this velocity is measured using Particle Image Velocimetry measuring technique and the results of the theoretically calculated velocity and the experimentally measured value are compared. The authors found a good agreement between the results of both approaches.