Remote Sensing (Aug 2020)

The Accuracy of Real-Time <i>h</i><sub>m</sub>F2 Estimation from Ionosondes

  • Carlo Scotto,
  • Dario Sabbagh

DOI
https://doi.org/10.3390/rs12172671
Journal volume & issue
Vol. 12, no. 17
p. 2671

Abstract

Read online

A total of 4991 ionograms recorded from April 1997 to December 2017 by the Millstone Hill Digisonde (42.6°N, 288.5°E) were considered, with simultaneous Ne(h)[ISR] profiles recorded by the co-located Incoherent Scatter Radar (ISR). The entire ionogram dataset was scaled with both the Autoscala and ARTIST programs. The reliability of the hmF2 values obtained by ARTIST and Autoscala was assessed using the corresponding ISR values as a reference. Average errors Δ and the root mean square errors RMSE were computed for the whole dataset. Data analysis shows that both the Autoscala and ARTIST systems tend to underestimate hmF2 values with |Δ| in all cases less than 10 km. For high magnetic activity ARTIST offers better accuracy than Autoscala, as evidenced by RMSE[ARTIST] [Autoscala], under both daytime and nighttime conditions, and considering all hours of the day. Conversely, under low and medium magnetic activity Autoscala tends to estimate hmF2 more accurately than the ARTIST system for both daytime and nighttime conditions, when RMSE[Autoscala] [ARTIST]. However, RMSE[Autoscala] slightly exceeds RMSE[ARTIST] for the day as a whole. RMSE values are generally substantial (RMSE > 16 km in all cases), which places a limit on the results obtainable with real-time models that ingest ionosonde data.

Keywords