Clinical Endoscopy (Jan 2024)

Comparison of scissor-type knife to non-scissor-type knife for endoscopic submucosal dissection: a systematic review and meta-analysis

  • Harishankar Gopakumar,
  • Ishaan Vohra,
  • Srinivas Reddy Puli,
  • Neil R Sharma

DOI
https://doi.org/10.5946/ce.2023.122
Journal volume & issue
Vol. 57, no. 1
pp. 36 – 47

Abstract

Read online

Background/Aims: Scissor-type endoscopic submucosal dissection (ST-ESD) knives can reduce the adverse events associated with ESDs. This study aimed to compare ST-ESD and non-scissor-type (NST)-ESD knives. Methods: We identified ten studies that compared the performance characteristics and safety profiles of ST-ESD and NST-ESD knives. Fixed- and random-effects models were used to calculate the pooled proportions. Heterogeneity was assessed using the I2 test. Results: On comparing ST-ESD knives to NST-ESD knives, the weighted odds of en bloc resection was 1.61 (95% confidence interval [CI], 0.90–2.90; p=0.14), R0 resection was 1.10 (95% CI, 0.71–1.71; p=0.73), delayed bleeding was 0.40 (95% CI, 0.17–0.90; p=0.03), perforation was 0.35 (95% CI, 0.18–0.70; p<0.01) and ESD self-completion by non-experts was 1.89 (95% CI, 1.20–2.95; p<0.01). There was no heterogeneity, with an I2 score of 0% (95% CI, 0%–54.40%). Conclusions: The findings of reduced odds of perforation, a trend toward reduced delayed bleeding, and an improvement in the rates of en bloc and R0 resection with ST-ESD knives compared to NST-ESD knives support the use of ST-ESD knives when non-experts perform ESDs or as an adjunct tool for challenging ESD procedures.

Keywords