Saudi Pharmaceutical Journal (Mar 2020)

Development of a simple high performance liquid chromatography (HPLC)/evaporative light scattering detector (ELSD) method to determine Polysorbate 80 in a pharmaceutical formulation

  • Bikash Mondal,
  • Mahesh Kote,
  • Chandrakant Lunagariya,
  • Milan Patel

Journal volume & issue
Vol. 28, no. 3
pp. 325 – 328

Abstract

Read online

The amount of polysorbate 80 in pharmaceutical formulations affects the product quality and efficacy. A reliable test method is required to quantify the amount of Polysorbate 80 present in the drug product formulations. The test method for the determination of Polysorbate 80 may be used during process development and final product quality assessment. A simple, fast and efficient quantitative method, making use of HPLC-ELSD and a C18 column without sample pretreatment was developed. The developed method demonstrated specificity to polysorbate 80 with high precision as indicated by percent relative standard deviation (%RSD) of 3.0% for six determinations. The accuracy of this method for the determination of polysorbate 80 in a pharmaceutical formulation was demonstrated with an overall recovery of 94.9%. Keywords: Method development, HPLC, ELSD, Polysorbate 80, Pharmaceutical formulation