Micromachines (Sep 2022)

Droplet Microfluidic Technology for the Early and Label-Free Isolation of Highly-Glycolytic, Activated T-Cells

  • Claudia Zielke,
  • Adriana J. Gutierrez Ramirez,
  • Kelsey Voss,
  • Maya S. Ryan,
  • Azam Gholizadeh,
  • Jeffrey C. Rathmell,
  • Paul Abbyad

DOI
https://doi.org/10.3390/mi13091442
Journal volume & issue
Vol. 13, no. 9
p. 1442

Abstract

Read online

A label-free, fixation-free and passive sorting method is presented to isolate activated T-cells shortly after activation and prior to the display of activation surface markers. It uses a recently developed sorting platform dubbed “Sorting by Interfacial Tension” (SIFT) that sorts droplets based on pH. After polyclonal (anti-CD3/CD28 bead) activation and a brief incubation on chip, droplets containing activated T-cells display a lower pH than those containing naive cells due to increased glycolysis. Under specific surfactant conditions, a change in pH can lead to a concurrent increase in droplet interfacial tension. The isolation of activated T-cells on chip is hence achieved as flattened droplets are displaced as they encounter a micro-fabricated trench oriented diagonally with respect to the direction of flow. This technique leads to an enrichment of activated primary CD4+ T-cells to over 95% from an initial mixed population of naive cells and cells activated for as little as 15 min. Moreover, since the pH change is correlated to successful activation, the technique allows the isolation of T-cells with the earliest activation and highest glycolysis, an important feature for the testing of T-cell activation modulators and to determine regulators and predictors of differentiation outcomes.

Keywords