Jornal Vascular Brasileiro ()

Morphometric analysis of rat femoral vessels under a video magnification system

  • Rui Sergio Monteiro de Barros,
  • Rafael Aquino Leal,
  • Renan Kleber Costa Teixeira,
  • Vitor Nagai Yamaki,
  • Felipe Lobato da Silva Costa,
  • Daniel Haber Feijó,
  • Andre Lopes Valente

DOI
https://doi.org/10.1590/1677-5449.011016
Journal volume & issue
Vol. 16, no. 1
pp. 73 – 76

Abstract

Read online

Abstract The right femoral vessels of 80 rats were identified and dissected. External lengths and diameters of femoral arteries and femoral veins were measured using either a microscope or a video magnification system. Findings were correlated to animals’ weights. Mean length was 14.33 mm for both femoral arteries and femoral veins, mean diameter of arteries was 0.65 mm and diameter of veins was 0.81 mm. In our sample, rats’ body weights were only correlated with the diameter of their femoral veins.

Keywords