He jishu (Aug 2024)
The development of scanning system of 1.2 MeV/10 mA electron accelerator in SESRI
Abstract
BackgroundThe 1.2 MeV/10 mA electron accelerator, as one of electron irradiation sources for comprehensive irradiation test chamber in Space Environment Simulation and Research Infrastructure (SESRI), can provide electron beams on the millimeter scale. However, the electron beam, as the electron irradiation source in space environment ground simulation experiment for aerospace, must be uniformly irradiated on large objects. Therefore, a well-suited irradiated technique is significant.PurposeThis study aims to obtain beam scanning with less than 10% of inhomogeneity for 0.6 MeV, 1.0 MeV, 1.2 MeV electron beam for SESRI.MethodsBased on the overall irradiation requirements, a specific beam-scanning system, including the scanning magnet with customized design, digital power supply and a dedicated apparatus for beam uniformity measurement, was developed. Particularly, in order to eliminate the influence of 45° incidence of electron beam upon scanning uniformity, an asymmetric and non-standard triangular waveform for the magnetic field excitation current was employed and implemented. The measurements for the beam non-uniformity were carried out on field experiments.ResultsExperimental results show that the scanning area of this electron accelerator reaches 1 000 mm×1 000 mm, and the scanning nonuniformity is less than 10% for variable beam energy from 0.6 MeV to 1.2 MeV, achieving the design goal and satisfying the irradiation requirements of SESRI.ConclusionsA specific beam-scanning system developed for SESRI is verified in this study, offering a good reference for any similar beam-scanning scenarios.
Keywords