Single-Chamber Cardiac Pacemaker Implantation in a Donkey with Complete AV Block: A Long-Term Follow-Up

  • Markéta Sedlinská,
  • Radovan Kabeš,
  • Miroslav Novák,
  • Filip Kološ,
  • Pavlína Melková

DOI
https://doi.org/10.3390/ani11030746
Journal volume & issue
Vol. 11, no. 3
p. 746

Abstract

Read online

A five-month-old African jenny was presented with a history of exercise intolerance and syncopal episodes. Severe bradycardic arrhythmia due to a high-grade second-degree atrioventricular (AV) block with progression to complete AV block was diagnosed. The jenny underwent a transvenous single-chamber pacemaker implantation. The implantation procedure was performed in a lateral recumbency and the ventricular lead was inserted through the jugular vein. Positioning of the lead was guided by echocardiography. The pacemaker was programmed to VVI mode with a minimal ventricular rate of 40 pulses per minute, a pulse amplitude of 2.4 V, a pulse width of 0.5 ms and sensing amplitude of 2.5 mV. Short-term complications associated with the procedure included lead dislodgement and pacemaker pocket infection. The long-term outcome was satisfactory; the jenny showed improvement in heart function and quality of life after pacemaker implantation. The pulse generator replacement was performed twice (at nine-year intervals) and the intervention was always associated with a local inflammatory reaction around the pacing device. Cardiac examination 18 years after pacemaker implantation revealed no morphological changes in the heart; the electrode lead was still in the correct position and successful pacing and sensing of the ventricle were obtained. Regular follow-up checks are important to evaluate pacemaker function.

Keywords