Бюллетень сибирской медицины (Jun 2012)

Evaluation of implant calcium-phosphate materials depending on their mineral content

  • I. A. Talashova,
  • T. A. Silantieva,
  • N. A. Kononovich,
  • S. N. Luneva

DOI
https://doi.org/10.20538/1682-0363-2012-3-62-68
Journal volume & issue
Vol. 11, no. 3
pp. 62 – 68

Abstract

Read online

Biocompatibility of original implant calcium-phosphate materials was evaluated in the experiment on animals. The methods of radiological electron-probe microanalysis (REMA) and light and scan electron microscopy (SEM) were used. Studied materials had the properties of biodegradation, osteoinduction and osteoconduction at different extent. The materials with the composite maximally close to the the bone tissue had the greatest grade of biocompatibility.

Keywords