MethodsX (Jan 2020)

Storage and initial processing of water samples for organic carbon analysis in runoff

  • Gunasekhar Nachimuthu,
  • Mark D Watkins,
  • Nilantha Hulugalle,
  • Lloyd A Finlay

Journal volume & issue
Vol. 7
p. 101012

Abstract

Read online

Runoff monitoring experiments are often conducted in remote sites. Sample collection and dispatch for analysis are often delayed due to sites’ remoteness and limited local laboratory facilities. The standard method of dissolved organic carbon (DOC) and total organic carbon (TOC) analysis in water samples requires storage of the samples at 4 °C after collection and analysis with a minimum of delay. However, there is no freezing storage time limit specified to avoid degradation. To overcome the limitations of this approach, we investigated the method of storage, that is refrigeration (4 °C) versus freezing (-18 °C), and the effect of storage time on DOC and TOC fractions in runoff water. Storage of samples at 4 °C for more than a week resulted in a decline of TOC and DOC concentrations in runoff water. • Freezing unfiltered water samples immediately after collection minimized TOC losses during storage, however, it may lead to variable DOC results. • Filtering a subsample of runoff or irrigation water immediately after collection using a 0.45 µm filter and freezing both the filtered and unfiltered samples until analysis of DOC and TOC, respectively, can minimize losses during storage.

Keywords