The Thoracic & Cardiovascular Surgeon Reports (Jan 2017)

Transcatheter Tricuspid Valve-In-Ring and Aortic Valve-In-Valve Implantation

  • Daniel Reichart,
  • Niklas Schofer,
  • Florian Deuschl,
  • Andreas Schaefer,
  • Stefan Blankenberg,
  • Hermann Reichenspurner,
  • Ulrich Schaefer,
  • Lenard Conradi

DOI
https://doi.org/10.1055/s-0037-1606345
Journal volume & issue
Vol. 06, no. 01
pp. e29 – e31

Abstract

Read online

Abstract Background Transcatheter heart valve (THV) therapies have shown to be an alternative to surgical valve replacement, especially in high-risk patients requiring redo surgery. However, reports of transcatheter-based interventions in tricuspid valve position are scarce. Case Description Here, we report a case of successful concomitant transcatheter aortic valve-in-valve (ViV) and tricuspid valve-in-ring (ViR) procedures using a 23-mm CoreValve Evolut R THV (Medtronic, Inc., Minneapolis, Minnesota, United States) in aortic position and a 29-mm SAPIEN3 (Edwards Lifesciences, Inc., Irvine, California, United States) THV in tricuspid position. Conclusion This case demonstrates feasibility of concomitant transcatheter aortic ViV and tricuspid ViR procedures.

Keywords