Machines (Mar 2024)

AC-Winding-Resistance Calculation of Toroidal Inductors with Solid-Round-Wire and Litz-Wire Winding Based on Complex Permeability Modeling

  • Dae-Yong Um,
  • Seung-Ahn Chae,
  • Gwan-Soo Park

DOI
https://doi.org/10.3390/machines12040228
Journal volume & issue
Vol. 12, no. 4
p. 228

Abstract

Read online

This paper has investigated a method for calculating the frequency-dependent winding resistance of toroidal inductor windings with Litz-wire as well as solid-round wire. The modified Dowell’s model is employed to address the effectiveness for inductor windings with the low and high filling factors. To overcome the limitation of this model, especially for a winding densely wound around the core, an alternative approach based on the complex permeability and iterative calculations is proposed. For the calculated AC-resistance factor of five inductors with different numbers of turns, layers with the same wire diameters are compared with that of FEA, and the three air-core toroidal windings are manufactured and tested within the frequency where the self-resonance can be neglected. The proposed model demonstrates the versality of the AC-resistance calculation of both solid- and Litz-wire windings within an error of 15% across a wide range of frequencies up to 1 MHz, compared with FEA.

Keywords