Сахарный диабет (Feb 2022)
The use of Flash glucose monitoring in children with type 1 diabetes mellitus in real clinical practice
Abstract
BACKGROUND: In 2018, a Frestyle Libre flash glucose monitoring system (FGM) appeared in Russia and became a potential alternative to the traditional CGM. Studies carried out to date have shown the advantages of FGM over SMBG, but only a few of them relate to real clinical practice, especially in children with type 1 diabetes.OBJECTIVE: To evaluate the efficacy of FGM in children with T1DM in relation to glycemic control indicators, the occurrence of severe hypoglycemia and diabetic ketoacidosis, as well as the satisfaction of patients and their parents with the use of FGM.MATERIALS AND METHODS: Single-center, prospective, observational cohort study. Children 4–18 years old with T1DM and HbA1c level less than 10.0% were invited to participate in the study on intensified insulin therapy (by MDI or CSII). The duration of the patient’s participation in the study was 6 months. At baseline and every 3 months thereafter, face-to-face consultations were conducted with an assessment of the general condition, HbA1c study, an assessment of glycemic indicators, progress in relation to glycemic control targets and correction of the therapy. A total of 228 patients (110 boys and 118 girls) who met the inclusion criteria were included in the study. The median age was 11.2 (8.6–14.7) years, the duration of type 1 diabetes was 3.8 (2–7.1), 136 patients received insulin therapy by CSII for 1.3 (0.8–2.6) years.RESULTS: In the general group of patients, 3 and 6 months after the start of FGM use, the HbA1c values decreased statistically significantly by 0.2%. In addition, the number of children with HbA1c <7.5% increased by 6.1 and 4.9% at 3 and 6 months, respectively, but these changes were not statistically significant. The number of cases of DKA when using FGM decreased by 74%, and the number of cases of severe hypoglycemia by 83%, thus the number of episodes decreased by 4 and 6 times, respectively. Patients and / or their parents rated the ease of use and their experience with FGM on a scale from 0 (strongly agree) to 4 (strongly disagree). The majority of children and parents positively (0 or 1) assessed the convenience of installing and wearing the sensor (72.7–98.2%) using the FGM system in general (75.0–96.4%) and in comparison with the SMBG glucometer (92.3–98.2%).CONCLUSION: The installation and use of FGM is convenient and comfortable for the vast majority of children and parents, while compared to SMBG, the use of FGM is more convenient and simpler, and glucose measurement is much faster and less painful.
Keywords