Micromachines (Nov 2022)

In-Process Analysis of Melt Pool Fluctuations with Scanning Optical Coherence Tomography for Laser Welding of Copper for Quality Monitoring

  • Thomas Will,
  • Tobias Jeron,
  • Claudio Hoelbling,
  • Lars Müller,
  • Michael Schmidt

DOI
https://doi.org/10.3390/mi13111937
Journal volume & issue
Vol. 13, no. 11
p. 1937

Abstract

Read online

Optical coherence tomography (OCT) is an inline process monitoring technology for laser welding with various applications in the pre-, in-, and post-process. In-process monitoring with OCT focuses on the measurement of weld depth by the placement of a singular measurement beam into the keyhole. A laterally scanned measurement beam gives the opportunity to measure the keyhole and melt pool width. The processing region can be identified by separating higher signal intensities on the workpiece surface from lower signal intensities from the keyhole and the melt pool. In this work, we apply a scanned measurement beam for the identification of keyhole fluctuations. Different laser processing parameters are varied for laser welding of copper to evoke welds in the heat conduction regime, stable deep penetration welding, and unstable deep penetration welding. As keyhole instabilities can be related to the generation of spatter and other defects, we identified a feature for the classification of different weld statuses. In consequence, feedback can be given about possible defects which are originated in keyhole fluctuations (e.g., spatter).

Keywords