Advances in Electrical and Electronic Engineering (Jan 2014)

Automatic Loss Adjustment for CDMA2000 and 1xEV-DO Standard for Downlink and Uplink

  • Jiri Kominek,
  • Miroslav Voznak,
  • Jan Zidek

DOI
https://doi.org/10.15598/aeee.v12i4.1214
Journal volume & issue
Vol. 12, no. 4
pp. 301 – 306

Abstract

Read online

The functional and thermal testing of the mobile phone is always performed under various conditions that vary in terms of the connection between the DUT (Device Under Test) and the measuring instrument. To achieve repeatable measurements under such conditions, it is necessary to adjust uplink and downlink loss using the instrument's external attenuation. While for GSM, WCDMA and LTE this is a relatively easy task, CDMA2000 and 1xEV-DO make automation of the adjustment process somewhat challenging due to the nature of the CDMA standard. An especially forward link is more complicated as those tests are run in signaling mode and not all instruments provide an FER value measured by an MS. This paper describes the algorithm for forward link loss adjustment and its implementation using Rohde & Schwarz CMW500.

Keywords