Science and Technology of Nuclear Installations (Jan 2023)

Design of a Nanosecond Voltage Comparator with PECL Logic for a Photon-Counting Radiation Imaging System Application

  • Huaxia Zhang,
  • Yuewen Sun,
  • Zijia Chen,
  • Zhifang Wu

DOI
https://doi.org/10.1155/2023/6810882
Journal volume & issue
Vol. 2023

Abstract

Read online

In this paper, a nanosecond voltage comparator with PECL logic for a photon-counting radiation imaging system is presented. To realize a high-speed comparison of four gamma detector channels in a limited board space, quad comparators MAX9602 with PECL logic are chosen. Each of the four channels is coupled with a PECL to CMOS converter ICS508, which exports CMOS logic data for later use in an FPGA. Simulated findings for cobalt-60 with intensities ranging from 30 Ci to 300 Ci show little count loss caused by using a comparator and indicate ideal propagation delays at all source intensities. While in the laboratory test using a PCB-level system, signals with pulse width less than 3 ns might be dropped, and dispersion of propagation delay occurs. Despite these, the performance is still satisfactory and can meet the requirements of practical applications, as demonstrated by an improved result of 0.9% in the contrast indicator model. Further studies to optimize the circuit design can be conducted to gain improvement.